Selbstkalibrierende Thermoelemente aus der Sicht von Kraftwerken und Entwicklern. - In: Vorträge V1 - V24, (2004), V13
Thin transparent pin-photodiodes for length measurements. - In: Sensors and actuators. Physical. - Amsterdam [u.a.] : Elsevier Science, 1990- , ISSN: 1873-3069 , ZDB-ID: 1500729-7, ISSN 1873-3069, Bd. 113 (2004), 3, S. 334-337
http://dx.doi.org/10.1016/j.sna.2004.03.067
Novel micro interferometer for length measurements. - In: Journal of non-crystalline solids, ISSN 0022-3093, Bd. 338/340 (2004), S. 793-796
http://dx.doi.org/10.1016/j.jnoncrysol.2004.03.093
Fibre-coupled homodyne interferometer for vibration analysis. - In: Photonics in measurement, (2004), S. 93-99
Richtiger Name des Verf.: Walter Schott
TNO TPD contributions to high-precision optical metrology, a Darwin metrology breadboard for ESA. - In: Space systems engineering and optical alignment mechanisms, (2004), S. 32-43
Richtiger Name des 5. Verfassers: Rainer Sesselmann
Anwendung von Miniaturinterferometern in Nanomessgeräten. - 11 S. = 605,5 KB, TextDruckausg.: Sensoren, Signale, Systeme : [10. Symposium über "Sensoren, Signale, Systeme" in der Technischen Akademie Esslingen 22. bis 24.06.2004] / Karl Walter Bonfig (Hrsg.). - Kreuztal : b-Quadrat Verl., 2004. - ISBN 3-933609-19-4, S. 187-198
http://www.db-thueringen.de/servlets/DocumentServlet?id=7274
A nanopositioning and nanomeasuring machine : operation-measured results. - In: Nami-jishu-yu-jingmi-gongcheng, ISSN 1672-6030, Bd. 2 (2004), 2, S. 81-84
An the Institute of Process Measurement and Sensor Technology of Technische Universität Ilmenau, a three-dimensional nanopositioning and nanomeasuring machine (NPM-Machine) has been developed. The Abbe offset-free design provides extra-ordinary accuracy. In the entire positioning and measuring range of 25 mm x 25 mm x 5 mm the interferometric length measurement system reaches a resolution of 0,1 nm and an uncertainty of 5 - 10 nm. The article gives basic information on this nanopositioning and measuring machine, explains its mode of operation and represents measurement results.
Application of self-calibrating thermometers with miniature fixed-point cells in a temperature range from 300 ˚C to 650 ˚C. - In: Proceedings, (2004), S. 1285-1290
Using integrated miniature fixed-point cells, a measuring uncertainty of < 1 K can be reached under operating conditions in the superheated steam range of power plants by a periodic recalibration of the thermocouples, with operating times of > 20000 h and also in other applications. The fixed-point materials used for a temperature range from 300 ˚C to 650 ˚C are technically pure metals and binary alloys.
Design and investigation of an optical standing-wave interferometer for displacement measurements. - In: Physics and applications of optoelectronic devices, (2004), S. 57-65
A novel class of sensors for system integrative concepts in biotechnological applications. - In: Technische Systeme für Biotechnologie und Umwelt, (2004), S. 163-169