Complete list of publications

Results: 995
Created on: Sun, 30 Jun 2024 16:29:10 +0200 in 0.0859 sec


Kurtash, Vladislav; Mathew, Sobin; Thiele, Sebastian; Scheler, Theresa; Reiprich, Johannes; Hähnlein, Bernd; Stauffenberg, Jaqueline; Manske, Eberhard; Narasimha, Shilpashree; Abedin, Saadman; Jacobs, Heiko O.; Pezoldt, Jörg
Hysteresis associated with intrinsic-oxide traps in gate-tunable tetrahedral CVD-MoS2 memristor. - In: IEEE 22nd International Conference on Nanotechnology (NANO), (2022), S. 527-530

We introduce back gated memristor based on CVD-grown 30-40 nm thick MoS2 channel. The device demonstrates bipolar behaviour and the measurements are consistent with the simulations performed within the intrinsic-oxide traps model. This confirms the theory that the source of hysteresis in thin-film MoS2 memristors is charge trapping on MoS2/SiO2 interface and the grain boundaries. The impact of back gate voltage bias, voltage sweep range and channel area on memristive effect was studied and quantified using hysteresis area. Hysteresis in bipolar memristors can be tuned by back gate voltage, which makes these devices promising for neuromorphic computing.



https://doi.org/10.1109/NANO54668.2022.9928717
Vasilyan, Suren; Fröhlich, Thomas; Rogge, Norbert
Einsatz von gepulsten Lasern mit hoher Leistung in der Präzisionskraftmesstechnik - ein Schritt in die Richtung einer künftigen, SI-rückführbaren und praktischen Kraftquantisierung durch Photonenimpulse :
Deploying the high-power pulsed lasers in precision force metrology - towards SI traceable and practical force quantization by photon momentum. - In: Technisches Messen, ISSN 2196-7113, Bd. 89 (2022), 11, S. 757-777

Design and operational performance of table-top measurement apparatus is presented towards direct Planck constant traceable high accuracy and high precision small forces and optical power measurements within the SI unit system. Electromagnetic force compensation weighing balances, highly reflective mirrors and high-energy pulsed laser unit (static average power 20 W) are tailored together with a specially developed opto-electro-mechanical measurement infrastructure for cross-mapping the scale-systems of two different precision small force measurement methods. One of these methods obtains the force measurements by a state-of-the-art classical kinematic system employing the partial use of Kibble balance principle in the range of 10 nN  to  4000 nN to be compared with forces generated due to quantum-mechanical effect namely the transfer of the momentum of photons from a macroscopic object. Detailed overview of the adapted measurement methodology, the static and the limits of dynamic measurement, the metrological traceability routes of the measurement parameters, quantities and their measurement uncertainties, parametric estimation of up (down)-scaling perspectives of the measurements are presented with respect to the state-of-the-art measurement principles and standard procedures within the newly redefined International System of Units (SI).



https://doi.org/10.1515/teme-2022-0080
Tobehn-Steinhäuser, Ingo; Herbst, Steffen; Xu, Xuemei; Ortlepp, Thomas; Barthelmann, Lukas; Krapf, Gunter
Redundante Temperatursensorik für das Batterien-Monitoring. - In: EASS, (2022), S. 42-46

Der Einsatz redundanter Temperaturmesssysteme erlaubt es, die Betriebssicherheit von Sensorsystemen deutlich zu erhöhen. Solche Systeme bestehen aus mindestens zwei Sensoren gleicher oder unterschiedlicher Technologie bzw. Kennlinie. Der erste Fall wird als homogene, der letzte als diversitäre Redundanz bezeichnet. Insbesondere der Ausfall eines einzelnen Sensors kann auf diese Weise zuverlässig detektiert werden. Darüber hinaus kann bei Berücksichtigung einer eingeschränkten Zuverlässigkeit auch weiterhin ein Messwert ermittelt werden. Vor diesem Hintergrund besteht u. a. im Bereich der Automobilindustrie zunehmend Bedarf an selbstvalidierender Sensorik dieser Art.



Shmagun, Vitalii; Gerhardt, Uwe; Fröhlich, Thomas; Manske, Eberhard; Kissinger, Thomas
Absolute distance measurements for in-situ interferometer characterisation using range-resolved interferometry. - In: Measurement science and technology, ISSN 1361-6501, Bd. 33 (2022), 12, 125024, S. 1-12

Range-resolved interferometry (RRI) allows the simultaneous demodulation of multiple interferometric signal sources and provides a tomographic view of all constituent interferometers that may be present in a setup. Through comparison with a reference distance of known length, absolute distance measurements can be performed. RRI is tailored to the use of laser frequency modulation through injection-current modulation of regular, monolithic laser diodes that are both cost-effective and highly coherent and therefore this approach promises broad applicability. In this paper, two methods for absolute distance measurement, one based on the direct evaluation of the signal peak positions and one based on the phase demodulation of an additional lock-in modulation signal, are experimentally demonstrated. Using an external verification displacement interferometer, both techniques are shown to achieve in-situ absolute distance measurements with systematic errors below over a 50 mm travel range. The aim of this paper is to establish the general suitability of RRI for absolute distance measurements and in-situ tomographic interferometer characterisation for precision engineering. In future, this approach could be used to diagnose interferometric setups for parasitic signal contributions, multiple reflections or to determine the dead path length for accurate environmental compensation, either for use during initial setup of, or for continuous operation alongside, a regular displacement measuring interferometer.



https://doi.org/10.1088/1361-6501/ac970a
Mathew, Sobin; Narasimha, Shilpashree; Reiprich, Johannes; Scheler, Theresa; Hähnlein, Bernd; Thiele, Sebastian; Stauffenberg, Jaqueline; Kurtash, Vladislav; Abedin, Saadman; Manske, Eberhard; Jacobs, Heiko O.; Pezoldt, Jörg
Formation and characterization of three-dimensional tetrahedral MoS2 thin films by chemical vapor deposition. - In: Crystal growth & design, ISSN 1528-7505, Bd. 22 (2022), 9, S. 5229-5238

A method to synthesize the three-dimensional arrangement of bulk tetrahedral MoS2 thin films by solid source chemical vapor deposition of MoO3 and S is presented. The developed synthesizing recipe uses a temperature ramping with a constant N2 gas flow in the deposition process to grow tetrahedral MoS2 thin film layers. The study analyses the time-dependent growth morphologies, and the results are combined and presented in a growth model. A combination of optical, electron, atomic force microscopy, Raman spectroscopy, and X-ray diffraction are used to study the morphological and structural features of the tetrahedral MoS2 thin layers. The grown MoS2 is c-axis oriented 2H-MoS2. Additionally, the synthesized material is further used to fabricate back-gated field-effect transistors (FETs). The fabricated FET devices on the tetrahedral MoS2 show on/off current ratios of 10^6 and mobility up to ∼56 cm^2 V^-1 s^-1 with an estimated carrier concentration of 4 × 10^16 cm-3 for VGS = 0 V.



https://doi.org/10.1021/acs.cgd.2c00333
Sommer, Klaus-Dieter; Fröhlich, Thomas; Schnelle-Werner, Olaf
Conference measurement uncertainty Erfurt 2021 :
Tagung Messunsicherheit Erfurt 2021. - In: Technisches Messen, ISSN 2196-7113, Bd. 89 (2022), 10, S. 645-646

https://doi.org/10.1515/teme-2022-0088
Blumröder, Ulrike; Köchert, Paul; Flügge, Jens; Füßl, Roland; Ortlepp, Ingo; Manske, Eberhard
Frequenzkamm-gekoppelte Metrologielaser für die interferometrische Längenmessung in Nanopositionier- und Nanomessmaschinen :
Comb-referenced metrology laser for interferometric length measurements in nanopositioning and nanomeasuring machines. - In: Technisches Messen, ISSN 2196-7113, Bd. 89 (2022), 10, S. 687-703

In this article a new approach for the direct traceability of interferometric length measurements in nanopositioning- and measuring machines is presented. The concept is based on an optical frequency comb tied to a GPS disciplined oscillator. The frequency comb serves as a highly stable reference laser with traceable optical frequencies. By directly stabilizing the metrology lasers of a nanopositioning and -measuring machine to a single comb line a permanent link of the laser frequency to an atomic clock is created allowing direct traceability to the SI meter definition. The experimental conditions to provide traceability will be discussed. Furthermore, it is demonstrated how the long-term frequency stability of an individual comb line can be transferred onto the metrology lasers enhancing their stability by three orders of magnitude.



https://doi.org/10.1515/teme-2022-0013
Häcker, Annika-Verena; Manske, Eberhard
Extensions for the design of a two photon based direct laser writer for large-area, high precision nanostructuring :
Erweiterungen zum Aufbau eines zwei Photonen basierten direkten Laserschreibers zur großflächigen, hochpäzisen Nanostrukturierung. - In: Technisches Messen, ISSN 2196-7113, Bd. 89 (2022), S. S55-S60

Zur Realisierung extrem feiner Strukturen spielen direkte Laserschreibprozesse, basierend auf Zwei-Photonen-Absorptionsverfahren (2PA), eine zentrale Rolle in der Mikro- und Nanofabrikation. Dafür ist neben einem Lasersystem ein hochpräzises Positioniersystem notwendig. Meist basieren diese Positioniersysteme auf Prinzipien, die ohne zusätzliche Stiching-Verfahren nur kleine Positionierbereiche ermöglichen. Für piezoelektrische Tische sind zum Beispiel nur einige hundert Mikrometer möglich. Auf Galvanometer-Scannern basierten Systemen können sogar nur Positionierbereiche von wenigen zehn Mikrometern realisiert werden. Um ohne zusätzliche Stiching Verfahren größere Fertigungsbereiche mit hoher Präzision für Mikro- und Nanostrukturierung zu ermöglichen, wurde ein Aufbau aus einem Femtosekundenlaser für 2PA und einer Nanopositionier- und Nanomessmaschine (NMM-1) entwickelt [3]. Die NMM-1 wurde an der TU Ilmenau zusammen mit der SIOS Meßtechnik GmbH entwickelt, mit einem Positioniervolumen von 25 mm × 25 mm × 5 mm und einer Positionierauflösung im Sub-Nanometerbereich. Dieser Aufbau wurde in den letzten Jahren weiter entwickelt und Strukturbreiten konnten reduziert werden [2]. Der Schwerpunkt liegt dabei auf der Entwicklung einer funktionalen Einheit aus Femtosekundenlaser und NMM-1. Dies soll die Komplexität erhöhen und die Homogenität der geschriebenen Strukturen stark verbessern.



https://doi.org/10.1515/teme-2022-0058
Oertel, Erik; Manske, Eberhard
A bottom-up approach for the radius and roundness measurement of micro spheres :
Ein Bottom-up Ansatz für die Radius- und Rundheitsmessung von Mikrokugeln. - In: Technisches Messen, ISSN 2196-7113, Bd. 89 (2022), S. S101-S106

Die mangelnde Verfügbarkeit von präzise charakterisierten Kugeln im Submillimeterbereich schränkt derzeit die Leistungsfähigkeit von Mikro- und Nano-Koordinatenmessgeräten ein. Aus diesem Grund werden am Institut für Prozessmess- und Sensortechnik der TU Ilmenau neue Ansätze zur Messung solcher Kugeln untersucht und daraus entsprechende Messverfahren entwickelt. Ein vielversprechender Ansatz basiert dabei auf einer Reihe von Oberflächenscans im Zusammenhang mit einem Stitching-Algorithmus. Als Oberflächensensor kommt zur Zeit ein Atomkraftmikroskop (AFM) im Kontaktmodus zum Einsatz. Eine rückführbare Messung erfordert eine präzise Charakterisierung der AFM-Spitzenform und deren Unsicherheit, um diesen Einfluss zu korrigieren und die Unsicherheit fortzupflanzen sowie möglichen Verschleiß der AFM-Spitze während des Messvorgangs festzustellen. Diese Aspekte fanden bisher keine Beachtung. Ausgehend von dem publizierten Stand wurde deshalb die Messstrategie und der Auswertealgorithmus durch eine geeignete Strategie zur Korrektur des Spitzenformeinflusses sowie der Ermittlung der Spitzenform erweitert. Diese wurde experimentell durch den Einsatz unterschiedlicher AFM-Spitzen mit nominellen Radien von 100 nm bis 2 μm an einer 300 μm-Rubin-Kugel untersucht. Im Rahmen des Beitrags werden dazu erste Ergebnisse vorgestellt und diskutiert.



https://doi.org/10.1515/teme-2022-0073
Pabst, Markus; Fröhlich, Thomas; Marin, Sebastian
Entwicklung eines neuartigen Magnetsystems für eine 1 kg-Planck-Waage :
Development of a novel magnet system for a 1 kg Planck balance. - In: Technisches Messen, ISSN 2196-7113, Bd. 89 (2022), S. S31-S36

The following paper presents the development of a novel magnet system for use in a 1 kg Planck balance. For this purpose, several preliminary theoretical and experimental investigations were carried out and an optimized prototype magnetic system was modeled, designed and built based on the results. Initial measurements showed that the magnet system with an outer diameter of 104 mm and a height of 50 mm achieved a constant average value of 85.25 N A^-1 at a range of motion of ±0.6 mm.



https://doi.org/10.1515/teme-2022-0043