Conference proceedings (congress papers, conference abstracts)

Results: 635
Created on: Sun, 30 Jun 2024 16:40:35 +0200 in 0.0920 sec


Vrdoljak, Pavo; Schalles, Marc
In situ single point calibration of thermometers by means of fix point cells :
In situ Einpunktkalibrierung von Thermometern mittels Fixpunkten. - In: Messunsicherheit praxisgerecht bestimmen und Prüfprozesse in der industriellen Praxis, (2017), S. 197-206

Schalles, Marc; Vrdoljak, Pavo
Kalibrierung von Thermometern in situ im Prozess. - Wunstorf, Germany : AMA Service GmbH. - 1 Online-Ressource (5 Seiten)Online-Ausgabe: 13. Dresdner Sensor-Symposium 2017 : 2017-12-04 - 2017-12-06, Hotel Elbflorenz, Dresden. - Wunstorf, Germany : AMA Service GmbH, 2017. - ISBN 978-3-9816876-5-1, S. 67-71

https://doi.org/10.5162/13dss2017/2.2
Schüler, Ralf; Dontsov, Denis; Mammen, Helge; Mengs, Enrico; Schalles, Marc; Fröhlich, Thomas
Schnelle Temperaturfühler zur Erfassung räumlicher Temperaturfelder in Luft. - In: Temperatur 2017, (2017), S. 183-188

Hohmann, Michael; Marin, Sebastian; Schalles, Marc; Fröhlich, Thomas
Validierung eines Blockkalibrator-Konzeptes mit integrierter Mehrfach-Fixpunktzelle und Wärmestromsensoren. - In: Temperatur 2017, (2017), S. 297-302

Schalles, Marc; Hohmann, Michael
Ermittlung der Unsicherheit von Thermometerkennlinien mittels Monte-Carlo-Simulation. - In: Temperatur 2017, (2017), S. 309-314

Pufke, Michael; Schalles, Marc
Aufbau und Erprobung eines Prüfstandes zum Vergleich von Rohranlegetemperaturfühlern. - In: Temperatur 2017, (2017), S. 189-194

In der vorliegenden Arbeit wird der Aufbau eines Prüfstandes zum Vergleich von Rohranlegetemperaturfühlern im Messbereich von 100 ˚C bis 150 ˚C näher beschrieben und durch Messungen zur Kurz- und Langzeitstabilität sowie den Umgebungseinflüssen charakterisiert. Weiterhin erfolgt der Vergleich von 3 ausgewählten kommerziellen Rohranlegefühlern.



Manske, Eberhard; Jäger, Gerd; Hausotte, Tino; Müller, Andreas; Balzer, Felix
Nanopositioning and Nanomeasuring Machine NPMM-200 - sub-nanometre resolution and highest accuracy in extended macroscopic working areas. - In: Proceedings of the 17th International Conference of the European Society for Precision Engineering and Nanotechnology, (2017), S. 81-82

At the Technische Universität Ilmenau, a new Nanopositioning and Nanomeasuring Machine NPMM 200 with a measuring range of 200 mm × 200 mm × 25 mm and a resolution of 0.02 nm has been developed. In order to achieve both highest nanometre accuracy and largest three-dimensional working space, an extended three-dimensional Abbe comparator principle is applied. The object to be measured is placed on a special mirror plate whose position in all six degrees of freedom is measured by high-precision multi-axis fibre-coupled laser interferometers. By means of an advanced closed-loop control tilt errors induced by the guiding systems can be minimized up to interferometric level. This paper presents the metrological concept, the realized design, the conditioning of environmental parameters as well as some first measuring results.



Oliveira, Rafael; Lepikson, Herman; Theska, René; Fröhlich, Thomas
Evaluation of the principle for generating reference inertial torques for the dynamic calibration of torque transducers. - In: Engineering for a changing world, (2017), insges. 11 S.

Brethauer, Andreas; Fröhlich, Thomas; Engels, Elmar
Comparison between different resistance thermometers at low immersion depths based on their heat conduction error :
Vergleich von unterschiedlichen Widerstandsthermometern bei niedrigen Eintauchtiefen bezüglich ihres Wärmeableitfehlers. - In: Technisches Messen, ISSN 2196-7113, Bd. 84 (2017), 12, S. 755-768

Der vorliegende Beitrag beschäftigt sich mit den Auswirkungen auf den Wärmeableitfehler eines Widerstandsthermometers beim Variieren der Eintauchtiefe in ein zu messendes Medium und der Füllhöhe einer Wärmeleitpaste im Schutzrohr. Dabei werden zudem unterschiedliche Bauformen von Widerstandsthermometern in Bezug auf ihren Wärmeableitfehler bei niedrigen Eintauchtiefen verglichen und Messergebnisse mit theoretischen Modellen sowie FEM-Simulation verglichen. Es zeigt sich, dass Füllhöhe und Wärmeleitfähigkeit der Wärmeleitpaste je nach Aufgabenstellung gewählt werden sollten. Gerade bei niedrigen Eintauchtiefen ist eine Anpassung der Füllhöhe an Sensorhöhe und Eintauchtiefe notwendig. Es kristallisiert sich zudem heraus, dass für eine genaue Vorhersage des Wärmeableitfehlers die FEM-Simulation der Modellrechnung überlegen ist. Auch wird die Bedeutung einer guten thermischen Kopplung des Sensors an das Medium und einer thermischen Entkopplung des Sensors von der anders temperierten Umgebung deutlich.



https://doi.org/10.1515/teme-2017-0060