Separation of physiological signals using minimum norm projection operators. - In: IEEE transactions on biomedical engineering, ISSN 1558-2531, Bd. 64 (2017), 4, S. 904-916
https://doi.org/10.1109/TBME.2016.2582643
Alginate-based hydrogels as an alternative to electrolytic gels for rapid EEG monitoring and easy cleaning procedures. - In: Sensors and actuators, ISSN 0925-4005, Bd. 247 (2017), S. 273-283
http://dx.doi.org/10.1016/j.snb.2017.02.164
Plant species classification using flower images - a comparative study of local feature representations. - In: PLOS ONE, ISSN 1932-6203, Bd. 12 (2017), 2, e0170629, insges. 29 S.
http://dx.doi.org/10.1371/journal.pone.0170629
Zwitterionic iron oxide (γ-Fe2O3) nanoparticles based on P(2VP-grad-AA) copolymers. - In: Macromolecular rapid communications, ISSN 1521-3927, Bd. 38 (2017), 4, S. 1600367, insges. 8 S.
Im Titel sind "2" und "3" tiefgestellt
http://dx.doi.org/10.1002/marc.201600637
Computation of Lorentz force and 3-D eddy current distribution in translatory moving conductors in the field of a permanent magnet. - In: IEEE transactions on magnetics, ISSN 1941-0069, Bd. 53 (2017), 2, S. 7000109, insges. 9 S.
Determination of the 3-D eddy current distribution inside a translatory moving conductor under a permanent magnet can accurately be done by using finite-element method (FEM). However, FEM calculations are very expensive, as they require discretization of the whole conductor volume. In this paper, we propose a new technique, to be called boundary element source method (BESM), where only boundary layers are discretized. The BESM is a modification of the hybrid boundary element method (HBEM). In the BESM, the concentrated point sources placed at the centers of boundary elements for the HBEM are replaced by distributed charge density over the area of the boundary element. This is especially useful in the regions, where neighboring boundary meshes significantly affect one another and when calculation point of eddy current is very close or belong to the surface of a boundary element. The method can handle arbitrary geometries of the specimen as well as the defect and arbitrary orientation of the magnetization vector. The accuracy of the proposed method is verified by comparing the results with the solutions obtained from a finite-element model. The proposed BESM approach is shown to be simple, robust, and computationally accurate.
https://doi.org/10.1109/TMAG.2016.2622223
Flexible Führung ultrakurzer Laserpulse in ophthalmologischen Therapiesystemen. - In: Klinische Monatsblätter für Augenheilkunde, ISSN 1439-3999, Bd. 234 (2017), 1, S. 109-116
http://dx.doi.org/10.1055/s-0042-121422
Source localization of S-cone and L/M-cone driven signals using silent substitution flash stimulation. - In: Biomedical engineering, ISSN 1862-278X, Bd. 62 (2017), 3, S. 339-348
https://doi.org/10.1515/bmt-2015-0240
Fractionation of magnetic microspheres in a microfluidic spiral: interplay between magnetic and hydrodynamic forces. - In: PLOS ONE, ISSN 1932-6203, Bd. 12 (2017), 1, e0169919, insges. 24 S.
http://dx.doi.org/10.1371/journal.pone.0169919
Hydrogen peroxide modulates energy metabolism and oxidative stress in cultures of permanent human Müller cells MIO-M1. - In: Journal of biophotonics, ISSN 1864-0648, Bd. 10 (2017), 9, S. 1180-1188
http://dx.doi.org/10.1002/jbio.201600201
Monitoring macular pigment changes in macular holes using fluorescence lifetime imaging ophthalmoscopy. - In: Acta ophthalmologica, ISSN 1755-3768, Bd. 95 (2017), 5, S. 481-492
https://doi.org/10.1111/aos.13269