Tagungsbeiträge

Anzahl der Treffer: 2032
Erstellt: Mon, 01 Jul 2024 23:04:29 +0200 in 0.0739 sec


Hotovy, Ivan; Predanocy, Martin; Hotovy, Juraj; Kups, Thomas; Spieß, Lothar; Wang, Chunyu; Rehacek, Vlastimil
Growth and characterization of indium oxide films for ozone detection. - In: Prospects in mechanical engineering, (2008), insges. 11 S.

http://www.db-thueringen.de/servlets/DocumentServlet?id=18741
Witte, Hartmut; Hoffmann, Martin; Liefeith, Klaus; Schnabelrauch, Matthias; Jandt, Klaus D.
ECM analogous biointerfaces for biomedical and biophysical applications. - In: Prospects in mechanical engineering, (2008), insges. 2 S.

http://www.db-thueringen.de/servlets/DocumentServlet?id=18043
Mämpel, Jörg; Stubenrauch, Mike; Fetter, Robert; Andrada, Emanuel; Jimenez-Lopez, Omar Eduardo; Witte, Hartmut; Fischer, Martin S.
InspiRat - technical biology: how to analyse vertebrate climbing. - In: Prospects in mechanical engineering, (2008), insges. 2 S.

http://www.db-thueringen.de/servlets/DocumentServlet?id=17938
Djamiykov, Todor; Milushev, Mladen; Hecht, Siegmar; Marinov, Marin
A sensor component of a walking machine's joint. - In: Prospects in mechanical engineering, (2008), insges. 2 S.

http://www.db-thueringen.de/servlets/DocumentServlet?id=17770
Bartsch de Torres, Heike; Rensch, Christian; Thelemann, Torsten; Müller, Jens; Hoffmann, Martin
Fully integrated bridge-type anemometer in LTCC-based microfluidic systems. - In: Advances in science and technology, ISSN 1662-0356, Bd. 54 (2008), S. 401-404

A thick film anemometer for in situ control of the flow rate in fluidic systems was designed, manufactured and characterized. The sensor is integrated in a retention modulus consisting of Low Temperature Cofired Ceramics (LTCC). These materials allow the cost-effective realisation of fluidic microsystems with integrated electronics. The challenge of the work is to design an anemometer under the exclusive use of thick film technologies. The necessity to trim resistors causes the external use of relevant pastes. Therefore, the use inside of a closed fluidic system requires the leak of process gases and, at the same time, a maximal heat-insulating of the sensor element from the substrate. Free-standing elements necessitate the control of stress due to shrinking mismatch, TCE mismatch, density gradients and deformation during the lamination. In the presented solution, embossed flue channels prevent blow forming on a free-standing bridge. The anemometer has a linear sensor characteristic for flow rates up to 0.1 ml/min. The layout guarantees that the fluid gets only in contact with the basic ceramic material, which is compatible with a wide range of biological substances. Therefore the sensor is applicable in contact with cell fluids or PCRreagents.



http://dx.doi.org/10.4028/www.scientific.net/AST.54.401
Kremin, Christoph; Stubenrauch, Mike; Hoffmann, Martin
Variations of nanostructured silicon in deep reactive ion etching processes. - In: Technical digest, (2008), S. 335-338

Brückner, Klemens; Niebelschütz, Florentina; Tonisch, Katja; Michael, Steffen; Dadgar, Armin; Krost, Alois; Cimalla, Volker; Ambacher, Oliver; Stephan, Ralf; Hein, Matthias
Multimode frequency response of piezoelectric AlGaN/GaN micro-electromechanical RF resonators. - In: Technical digest, (2008), S. 165-168

Polster, Tobias; Albrecht, Arne; Hoffmann, Martin
Thin free standing AlN membranes - mechanical stable and flexible structural material for MEMS devices. - In: Technical digest, (2008), S. 85-88

Stubenrauch, Mike; Fröber, Ulrike; Voges, Danja; Schilling, Cornelius; Witte, Hartmut; Hoffmann, Martin
Bio-MEMS with integrated polymer scaffolds for tissue engineering. - In: Technical digest, (2008), S. 65-68

Morales, Francisco M.; Lozano, Juan Gabriel; García, Rafael; Lebedev, Vadim; Hauguth-Frank, Sindy; Cimalla, Volker; Ambacher, Oliver; González, David
Study of microstructure and strain relaxation on thin InXGa1-xN epilayers with medium and high In contents. - In: Materials science, ISBN 978-3-540-85225-4, (2008), S. 77-78